Sök artiklar i SveMed+

Observera: SveMed+ upphör att uppdateras!



Maskinell differensialtelling av hvite blodceller i leddvaeske
Engelsk titel: Automated differential counting of white blood cells in synovial fluid Läs online Författare: Lingaas, Kristin ; Andersen, Heidi ; Hersleth, Inger Berit Språk: Nor Antal referenser: 7 Dokumenttyp: Artikel UI-nummer: 10033313

Tidskrift

Bioingeniören 2009;44(1)6-8 ISSN 0801-6828 E-ISSN 1890-1875 KIBs bestånd av denna tidskrift

Sammanfattning

Diakonhjemmet Hospital has a large rheumatology department, with regional responsibility for rheumatic disorders in adults. Our former reference method for the differential count of WBC's in synovial fluid was based on microscopy, which was very time-consuming. The purpose of our project was to examine whether our automatic analyser, Coulter LH 750, could carry out a differential count of WBC's in synovial fluid, not only total WBC. Determination of the differential WBC count in synovial fluid using Coulter LH 750 is highly correlated to the reference method. Automatic WBC count is faster and analysis more precise than manual count. Our findings demonstrate that the differential count of WBC in synovial fluid is therefore useful for both patients and physicians.


MeSH

Engelska MeSH-termer