Perkutan kateterbasert innsetting av kunstig pulmonalklaff ved medfödt hjertefeil
Engelsk titel: Percutaneous catheter-based implantation of artificial pulmonary valves in patients with congenital heart defects Läs online Författare: Wyller, Vegard Bruun ; Aaberge, Lars ; Thaulow, Erik ; Döhlen, Gaute Språk: Nor Antal referenser: 12 Dokumenttyp: Artikel UI-nummer: 11071645

Tidskrift

Tidsskrift for Den Norske Laegeforening 2011;131(13-14)1289-93 ISSN 0029-2001 E-ISSN 0807-7096 KIBs bestånd av denna tidskrift Denna tidskrift är expertgranskad (Peer-Reviewed)

Sammanfattning

Background. Percutaneous catheter-based implantation of artificial heart valves is a new technique that may supplement surgery and which may be used more in the future. We here report our first experience with implantation of artificial pulmonary valves in children with congenital heart defects. Material and methods. Eligible patients were those with symptoms of heart failure combined with stenosis and/or insufficiency in an established artificial right ventricular outflow tract. The valve was inserted through a catheter from a vein in the groin or neck. Symptoms, echocardiography, invasive measurements and angiography were assessed for evaluation of treatment effect. Our treatment results are reported for the period April 2007 - September 2009. Results. Ten patients (seven men and three women, median age 17 years) were assessed. The procedure reduced pressure in the right ventricle (p = 0.008) and resolved the pulmonary insufficiency in all patients. The median time in hospital was two days. No patients had complications that were directly associated with the implantation procedure. One patient developed a pseudoaneurism in the femoral artery, another had a short-lasting fever two days after the procedure and one patient experienced a stent fracture that required surgery 9 months after the implantation. After 6 months all patients had a reduced pressure gradient in the right ventricular outflow tract (p = 0.008), the pulmonary insufficiency had improved (p = 0.006) and they all reported improval of symptoms. These results persisted for at least 24 months for the four patients who were monitored until then. Interpretation. Percutaneous catheter-based implantation of artificial pulmonary valves improves hemodynamics in the right ventricle of selected patients with congenital heart defects. A randomized controlled study should be undertaken to provide a stronger evidence-base for usefulness of this procedure.