Scoringssystem til tidlig opsporing af kritisk sygdom kan fejle
Engelsk titel: Scoring system for early detection of critical illness can fail Läs online Författare: Kamstrup Christiansen, Laerke ; Bönding Andreasen, Jo ; Alcaraz Frederiksen, Christian ; Juhl-Olsen, Peter ; Sloth, Erik Språk: Dan Antal referenser: 5 Dokumenttyp: Fallbeskrivning UI-nummer: 13047154

Tidskrift

Ugeskrift for Laeger 2013;175(8)486-7 ISSN 0041-5782 E-ISSN 1603-6824 KIBs bestånd av denna tidskrift Denna tidskrift är expertgranskad (Peer-Reviewed)

Sammanfattning

A 57-year old male underwent elective aortic valve replacement. The immediate post-operative course was uneventful and the patient was discharged with the lowest possible score on a newly implemented scale for early detection of critical illness. The following day he was readmitted with dyspnoea. The critical illness score was still low despite ultrasonic demonstration of a large pericardial effusion requiring drainage. We are concerned that the widely adopted critical illness scale is not sufficiently sensitive for cardiac surgery patients and advocate the use of point-of-care ultrasound.