Sök artiklar i SveMed+

Observera: SveMed+ upphör att uppdateras!



Forbigående tab af balancefunktionen efter cochlear implantation
Engelsk titel: Temporary loss of vestibular function after cochlear implant surgery Läs online Författare: Korsager, Leise Elisabeth Hviid ; Schmidt, Jesper Hvass ; Faber, Christian ; Wanscher, Jens Höjberg Språk: Dan Antal referenser: 5 Dokumenttyp: Fallbeskrivning UI-nummer: 17030101

Tidskrift

Ugeskrift for Laeger 2017;179(3)254-5 ISSN 0041-5782 E-ISSN 1603-6824 KIBs bestånd av denna tidskrift Denna tidskrift är expertgranskad (Peer-Reviewed)

Sammanfattning

Loss of vestibular function is a common side effect to cochlear implant (CI) surgery. We present a patient who experienced balance problems and showed a reduced vestibulo-ocular reflex (VOR) gain (0.47 ± 0.10) combined with saccades in the horizontal semicircular canals demonstrated by the video head im­pulse test the day after CI surgery. One month after the operation VOR gain was normal (0.95 ± 0.05) and neither balance problems nor saccades occurred. Our findings indicate that vestibular dysfunction after CI surgery can be reversible, and VOR gain can return to normal.