Svaer diare efter skift fra velfungerende perkutan endoskopisk gastrostomisonde til Mic-key-knap
Engelsk titel: Severe diarrhea after the original well-functioning percutaneous gastrostomy tube was replaced by a Mic-Key button
Läs online
Författare:
Wigh Jensen S
;
Eriksen J
;
Kristensen K
Email: hecswj@ringamt.dk
Språk: Dan
Antal referenser: 5
Dokumenttyp:
Fallbeskrivning
UI-nummer: 06031776
Sammanfattning
We report two cases of colocutaneous fistula as a complication of percutaneous endoscopic gastrostomy (PEG) in small children. Both children developed severe osmotic diarrhoea immediately after the original PEG tube was replaced by a Mic-Key button which subsequently migrated to the colon.