Sök artiklar i SveMed+

Observera: SveMed+ upphör att uppdateras!



Svaer diare efter skift fra velfungerende perkutan endoskopisk gastrostomisonde til Mic-key-knap
Engelsk titel: Severe diarrhea after the original well-functioning percutaneous gastrostomy tube was replaced by a Mic-Key button Läs online Författare: Wigh Jensen S ; Eriksen J ; Kristensen K Språk: Dan Antal referenser: 5 Dokumenttyp: Fallbeskrivning UI-nummer: 06031776

Tidskrift

Ugeskrift for Laeger 2006;168(10)1038-9 ISSN 0041-5782 E-ISSN 1603-6824 KIBs bestånd av denna tidskrift Denna tidskrift är expertgranskad (Peer-Reviewed)

Sammanfattning

We report two cases of colocutaneous fistula as a complication of percutaneous endoscopic gastrostomy (PEG) in small children. Both children developed severe osmotic diarrhoea immediately after the original PEG tube was replaced by a Mic-Key button which subsequently migrated to the colon.