Sök artiklar i SveMed+

Observera: SveMed+ upphör att uppdateras!



Falskt förhöjd kreatininnivå orsakades av M-komponent
Engelsk titel: Falsely elevated plasma creatinine due to monoclonal gammopathy Läs online Författare: Tjernberg, Ivar ; Gustafsson, Inger Språk: Swe Antal referenser: 4 Dokumenttyp: Fallbeskrivning UI-nummer: 18020209

Tidskrift

Läkartidningen 2018;115(4)142-3 ISSN 0023-7205 E-ISSN 1652-7518 KIBs bestånd av denna tidskrift Denna tidskrift är expertgranskad (Peer-Reviewed)

Sammanfattning

Analytical interference may give rise to falsely elevated as well as reduced clinical biochemical results. Hemolysis, icterus and lipemia in patient samples are well-known causes of analytical interference. Laboratories usually automatically check for these interferences and take them into account. However, other causes of interference are more difficult to detect, such as those caused by heterophilic antibodies and in this case a falsely elevated plasma creatinine level caused by a monoclonal IgM gammopathy. Analytical interference should be considered in cases with unexpected laboratory results and inconsistent pattern of results, in which contact and discussion with the laboratory is advised.